Peak and Continuous Power Graphs

for HPEVS AC-34 Oil Cooled Motor

Header Content Region

Insert text, image or banner ads here, or just delete this text and leave this area blank!

hpevs golf car lithium battery pack eletric GT Ferrari 308 GTE EM parking Brake for golf cars HPEVS AC electric motors for golf cars HPEVS New software package HPEVS Curtis Controllers dimensional information HPEVS Oil Cooled AC Electric Motor for Marine Vessels EV West Factory Five build HPEVS Troubleshoot and Diagnostics HPEVS 144 volt Drive System HPEVS AC Electric Motor for Mining Industry HPEVS AC Electric motor, 96 Volt Drive System HPEVS AC electric motors for motorcycles HPEVS AC electric motors for industrial vehicles
We have Designed and Developed A Lithium-Ion Battery Kit For Golf Cars That Is Completely Integrated With The HPEVS Golf Car AC Drive Systems

It is Amazing To Us To See What Can Be Done With Our Drive Systems! Here Is Yet Another Example!

Our "Original" AC Drive System For Golf Cars Just Got A Whole Lot Better With The Introduction of an Automatic Parking Brake!!

Golf Car Systems


The "original", and still the best AC drive system available for your golf car!




To get information, please click on "Details" tab below.
We Have Developed a New Generic Software Package

New additions to this package include OBDII and Curtis Instruments enGage VII display support.


To get information, please click on "Details" tab below.

We have added to our website dimensional drawings of the Curtis Instruments controllers.

These drawings can be helpful during the design phase of a project.

To get information, please click on "Details" tab below.

We Are Pleased To Announce Our New Line of Oil Cooled Motors.

These motors have a stainless steel frame, anodized aluminum junction box and end bells, totally sealed and oil cooled.

To get information, please click on "Details" tab below.

The Folks at EV West Have Created a Vehicle with One of Our Drive Systems!




To get information, please click on "Details" tab below.

Diagnostic and Troubleshooting Documentation.






To obtain this information, please click on "Details" tab below.

144 Volt Automobile Systems

The Scion pictured has the first prototype!




Mining Vehicle Systems

Specialty motors designed and built for your specific applications!






To get information, please click on "Details" tab below.
96 Volt Automotive Systems

This is one of many systems available for auto conversions!




To get information, please click on "Details" tab below.
Motorcycle Systems

WHAT A RUSH!!






To get information, please click on "Details" tab below.
Utility Vehicle Systems


We have a drive system to fulfill your utility vehicle requirements!





To get information, please click on "Details" tab below.
small portfolio1 small portfolio2 small portfolio3 small portfolio4 small portfolio5
Innovation in Motion, Powered by Electricity
get in touch
Links to our main drive system page
HPEVS Drive Systems

Our are powerful, efficient and reliable. Find out what our drive systems can do for your project.
Power Graphs Link

The power graphs can be accessed by clicking on the above graphic.
Schematics, Instructions and Troubleshooting

To assist you, our customers, we have compiled all the documentation needed to wire, program and troubleshoot. The wiring diagrams include documentation for on-road vehicles, golf cars and hydraulic pump applications. Click on the graphic above to open the page with the information.

Main Menu:

What's New

We have included a variation of the AC-20 motor called AC-23! The motor is wound to produce higher torgue compared to the AC-20 motor! Please check AC-2X motor page for more information!
AC 2x Family of Motors

Newsletter Signup

Recent Events

Describe the photo or the page it links to

The Recent Events content includes an image that 'AUTO' scales. No need to resize the image, the CSS style sheet will resize the images for you, once rendered in your web page.

HPEVS AC Electric Oil Cooled AC-34 Motor Power Graphs





Published graphs are for INFORMATIONAL purposes ONLY and are NOT intended to be used to calculate motor efficiencies.

  • Description
  • Instructions
  • Oil Cooled AC-34


Our new Stainless Steel Oil Cooled AC-34 Motor is a new addition to the HPEVS AC-3X family of motors. The attached graphs are the updated dyno numbers that we have attained in house. The peak horsepower has not changed. We have added the graphs containing the continuous data (3-6-15).

Your continuous horsepower ratings will vary based on the design and efficiency of the oil cooling system.


Instructions

1. Click on the tab for the motor of interest.

2. When the tab has been selected, the tab will turn to a gray background. This signifies that the tab selected is active.

3. First, select the motor you want information on

4. Then select either imperial or metric

5. Next, select the voltage

6. And finally select either "Peak Graphs" or "Continuous Graphs".

7. If you selected the "Peak Graphs", select the amperage that you want to look at.

  • Imperial
  • Metric
  • 48 Volt
  • 72 Volt
  • 96 Volt
  • 108 Volt
  • 48 Volt Peak Graph
  • Continuous Graphs
AC34 at 48 Volts/650 Amps
Imperial Peak
ac34 48volts 650 amp imperial peak
Click on image for PDF file to print.

AC34 at 48 Volts
Oil Cooling
Imperial Continuous

AC34 at 72 Volts imperial continuous oil cooled

Click on image for new window to print.

  • 72 Volt Peak Graph
  • Continuous Graphs
  • 550 amp
  • 650 amp
AC34 at 72 Volts/550 Amps
Imperial Peak
ac35 72 volt 550 amps
Click on image for PDF file to print.

ac36 72 volt 550 amp imperial peak
AC34 at 72 Volts
Oil Cooling
Imperial Continuous

AC34 at 72 Volts imperial continuous oil cooled

Click on image for new window to print.

AC34 at 72 Volts
Oil Cooling
Imperial Continuous

AC34 at 72 Volts imperial continuous oil cooled

Click on image for new window to print.

  • 96 Volt Peak Graph
  • Continuous Graphs
  • 650 amp
AC34 at 96 Volts/650 Amps
Imperial Peak
ac35 96 volt 650 amps
Click on image for PDF file to print.

ac36 962 volt 650 amp imperial peak
AC34 at 96 Volts
Oil Cooling
Imperial Continuous

AC34 at 96 Volts imperial continuous oil cooled

Click on image for new window to print.

  • 108 Volt Peak Graph
  • 650 amp
AC34 at 108 Volts/650 Amps
Imperial Peak
ac35 108 volt 650 amps
Click on image for PDF file to print.

ac36 108 volt 650 amp imperial peak
  • 48 Volt
  • 72 Volt
  • 96 Volt
  • 108 Volt
  • 48 Volt Peak Graph
  • Continuous Graphs
AC34 at 48 Volts/650 Amps
Metric Peak
ac-34 48 volt 650 amp metric peak
Click on image for PDF file to print.

AC34 at 48 Volts
Oil Cooling
Metric Continuous

AC34 at 48 Volts metric continuous oil cooled

Click on image for new window to print.

  • 72 Volt Peak Graph
  • Continuous Graphs
  • 550 amp
  • 650 amp
AC34 at 72 Volts/550 Amps
Metric Peak
ac35 72 volt 550 amps
Click on image for PDF file to print.

AC34 at 72 Volts/650 Amps
Metric Peak
ac35 72 volt 650 amps
Click on image for PDF file to print.

ac36 72 volt 650 amp metric peak
AC34 at 72 Volts
Oil Cooling
Metric Continuous

AC34 at 72 Volts metric continuous oil cooled

Click on image for new window to print.

  • 96 Volt Peak Graph
  • Continuous Graphs
  • 650 amp
AC34 at 96 Volts/650 Amps
Metric Peak
ac35 96 volt 650 amps
Click on image for PDF file to print.

ac36 96 volt 650 amp metric peak
AC34 at 96 Volts
Oil Cooling
Metric Continuous

AC34 at 96 Volts metric continuous oil cooled

Click on image for new window to print.

  • 108 Volt Peak Graph
  • 650 amp
AC34 at 108 Volts/650 Amps
Metric Peak
ac35 108 volt 650 amps
Click on image for PDF file to print.

ac34 108 volt 650 amp metric peak
slide up button